Pakistan Cables 10mm² Pure Copper Wire – 90m Coil (Industrial Main Supply & Large ACs)
Rs.53,375.00Rs.62,794.00
🔥 Loading...
👀 Loading viewers...
Hurry up! so you don't miss out the best rates
Delivery within 2 Days in Karachi
Delivery within 5-10 Days outside Karachi
Pakistan Cables 10mm² Pure Copper Wire – 90m Coil (Industrial Main Supply & Large ACs) Pakistan Cables 10mm² pure copper... Read more Read more
Share with your friends Share WhatsApp Deel X Pin it Messenger Email
Description
Pakistan Cables 10mm² Pure Copper Wire – 90m Coil (Industrial Main Supply & Large ACs)
Pakistan Cables 10mm² pure copper wire represents industrial-grade heavy-duty cabling for main electrical service entrances, 5+ ton central AC systems, large industrial pumps, factory main feeders, and high-current solar installations. 99.99% pure copper conductor with flame-retardant PVC insulation (450/750V rating) – exclusively for professional contractors handling major electrical projects in Karachi, Lahore, Faisalabad, Multan, and nationwide industrial hubs.
Why 10mm²? Maximum Capacity Power Distribution (50-70A)
-
Main service entrance from transformer/meter to main panel (200-500 sqm facilities)
-
5+ ton central AC systems or multiple 3-ton splits
-
5-10HP industrial pumps and motors
-
Factory main lighting + machine feeders
-
Large commercial buildings main supply
-
Solar main DC cables for 10kW+ systems (inverter input)
Pakistan Cables 10mm² Technical Specifications
Conductor: 99.99% Pure Copper (multi-strand maximum conductivity)
Cross Section: 10mm² nominal (approx. AWG 8 equivalent)
Gauge: 10mm² single core heavy duty
Insulation: FR PVC (Flame Retardant 70°C continuous)
Voltage Rating: 450/750V AC (over-spec for 250/440V systems)
Coil Length: Exact 90 meters factory guaranteed
Ampacity: 50-70A in conduit (30°C ambient, PVC insulated)
Colors Available: Red, Yellow, Blue, Black, Green/Yellow (earth)
Standards: BS 6004, IEC 60227, Pakistan Cables certified
Weight: 9-11kg per full 90m coil
Real-World Heavy Duty Applications
Pakistan Cables 10mm² | Local Heavy Brands | Chinese Industrial
✅ 99.99% Pure Copper | ❌ 90-94% Mixed | ❌ CCA/Mixed
✅ Exact 90m Coil | ❌ 82-87m | ❌ 78-85m
✅ FR PVC 75°C | ❌ Basic PVC | ❌ Thin PVC
✅ BS 6004/IEC Cert | ❌ Minimal | ❌ Fake Certs
✅ 35yr Lifespan | ❌ 12-15yr | ❌ 7-10yr
✅ 99.99% Pure Copper | ❌ 90-94% Mixed | ❌ CCA/Mixed
✅ Exact 90m Coil | ❌ 82-87m | ❌ 78-85m
✅ FR PVC 75°C | ❌ Basic PVC | ❌ Thin PVC
✅ BS 6004/IEC Cert | ❌ Minimal | ❌ Fake Certs
✅ 35yr Lifespan | ❌ 12-15yr | ❌ 7-10yr
MANDATORY: Engineering calculations required for voltage drop, breaker coordination, and thermal protection.
10mm² vs 6mm² vs 16mm² Sizing Guide
| Application | 6mm² | 10mm² | 16mm² |
|---|---|---|---|
| 5-ton Central AC | ✅ Short | ✅ Long | Overkill |
| Main Panel 200A House | ❌ No | ✅ Perfect | Good |
| 5HP Industrial Pump | ⚠️ Limit | ✅ Yes | Perfect |
| Factory Main Feeder | ❌ No | ✅ Yes | Better |
| Solar 10kW Main | ✅ Short | ✅ Long | Perfect |
Pakistan Cables 10mm² vs Import/Local Competition
Pakistan Cables 10mm² | Local Heavy Brands | Chinese Industrial
✅ 99.99% Pure Copper | ❌ 90-94% Mixed | ❌ CCA/Mixed
✅ Exact 90m Coil | ❌ 82-87m | ❌ 78-85m
✅ FR PVC 75°C | ❌ Basic PVC | ❌ Thin PVC
✅ BS 6004/IEC Cert | ❌ Minimal | ❌ Fake Certs
✅ 35yr Lifespan | ❌ 12-15yr | ❌ 7-10yr
✅ 99.99% Pure Copper | ❌ 90-94% Mixed | ❌ CCA/Mixed
✅ Exact 90m Coil | ❌ 82-87m | ❌ 78-85m
✅ FR PVC 75°C | ❌ Basic PVC | ❌ Thin PVC
✅ BS 6004/IEC Cert | ❌ Minimal | ❌ Fake Certs
✅ 35yr Lifespan | ❌ 12-15yr | ❌ 7-10yr
Professional Installation – Industrial Standards
⚠️ HIGH VOLTAGE/HIGH CURRENT ⚠️
1. 63A-100A breakers MAXIMUM (confirm with load calc)
2. 32-40mm heavy duty PVC conduit REQUIRED
3. Hydraulic crimping tools for termination
4. Lugs M8-M10 size minimum
5. Earth conductor 6mm² minimum parallel
6. Megger insulation test >100 MΩ
7. Thermal imaging post-installation
8. PEC licensed contractor mandatory
1. 63A-100A breakers MAXIMUM (confirm with load calc)
2. 32-40mm heavy duty PVC conduit REQUIRED
3. Hydraulic crimping tools for termination
4. Lugs M8-M10 size minimum
5. Earth conductor 6mm² minimum parallel
6. Megger insulation test >100 MΩ
7. Thermal imaging post-installation
8. PEC licensed contractor mandatory
Frequently Asked Questions
Q: What is the absolute maximum load?
A: 70A continuous in conduit at 30°C ambient. Derate for higher temperatures and long runs. Engineering required.
Q: Single phase or three phase safe?
A: Safe for single phase heavy loads up to house main supply. Three phase requires 3-core configuration.
Q: Can handle 10-ton AC system?
A: No single core. Use 3x10mm² or consult engineer for parallel runs.
Q: Coil length accuracy?
A: Factory precise 90 meters – Pakistan Cables industrial standard.
Q: Pure copper conductivity proof?
A: 99.99% electrolytic copper – BS 6004 verified resistivity 1.724 µΩ·m max.
Q: Large solar farm main line?
A: Yes for DC main cables up to 80A (panels → MPPT → inverter). Use armoured for outdoor >50m.
Q: Karachi industrial delivery?
A: FREE next day for 5+ coils. Lahore 48hrs, other cities 3 days.
Q: Compared to 6mm² performance?
A: 10mm² = 60% more current capacity, 50% less voltage drop over distance.
Buy Genuine Pakistan Cables 10mm² – ChachaTrader Industrial
ADD TO CART – Best Price Pakistan Cables 10mm Wire 90m Industrial Grade
ChachaTrader Contractor Benefits:
✅ Factory direct genuine stock
✅ Exact 90m coils (11kg verification)
✅ FREE bulk Karachi delivery
✅ Nationwide COD for contractors
✅ Volume pricing 5+ coils
✅ Free engineering consultation
Colors: Red | Yellow | Blue | Black | Green/Yellow Earth
Contractor Bulk: 20+ coils = free 25mm conduit pipe + priority delivery!